Mobotix HTTP control of BrickElectric relay controller.
Search and replace the below text and replace '10.13.0.105' with your BCOM unit IP address.
SECTION ipnotify profile=ip_59719ffb:_profilename=BCOM-R1-TIMER:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K01%3D5:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970a130:_profilename=BCOM-R1-TOGGLE:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K01%3D2:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970aa63:_profilename=BCOM-R1-ON:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K01%3D1:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970aa71:_profilename=BCOM-R1-OFF:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K01%3D0:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5971a031:_profilename=BCOM-R2-TIMER:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K02%3D5:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970a9f5:_profilename=BCOM-R2-TOGGLE:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K02%3D2:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970aab1:_profilename=BCOM-R2-ON:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K02%3D1:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970aaeb:_profilename=BCOM-R2-OFF:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/K02%3D0:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 profile=ip_5970a2e0:_profilename=BCOM-REBOOT:preset=custom:ackn_time=60:ipnotifyaddress=10.13.0.105%3A80:send=parallel:protocol=http10:boundary=:httppath=/reboot%3D1:httpauth=:data=msg:ipnotifymessage=:filetype=mxg:rate100=100:antetime=1:posttime=1:systime=0:ipnotifyport=0 ENDSECTION ipnotify
Go to http://[IP_OF_CAMERA]/admin/showconfig?edit. Find "SECTION ipnotify" and add the above text within that section.
This will enable reboot, timer (1 sec by default) and toggle on/off for 2 x relays via as actions for your various events.
Test with UC or http://[IP_OF_CAMERA]/admin/nettest