Load single Auto-P parameters to Yealink phone

Modified on Thu, 18 Mar, 2021 at 4:10 PM

To load a single auto-provisioning value line into a Yealink phone you can force load that via the Auto-provisioning Server URL field by prefixing it with M7: save then click auto-provision now.


M7:parameter=value


example 


M7:network.redundancy.mode=1


image.png


NOTE: This is considered an advanced but experimental developer feature and should not be used by general users.